• #maker+t=market
  • 3D列印服務
  • 1
  • 2

ATOM 3D Printer Group 造訪社團

原文網址 Harry Liu
2015-04-10 12:43:26

請問,左右兩邊很容易翹起來,是什麼問題?(除此之外,升級版真的很強!)

Bato Wang
2015-04-10 12:49:31

有幾種方式...1. 開Raft...2.膠塗多一點. 3容易翹的地方加上mouse ears....

Stanley Chen
2015-04-10 12:56:23

4.印到2mm左右點快乾

Harry Liu
2015-04-10 12:57:43

目前的Raft : Type=Skirt / Inflat=10 , 要怎麼改比較好?

Clarence Lee
2015-04-10 13:05:20

開brim也可.. 張到10mm

Harry Liu
2015-04-10 13:09:29

稍微翹起來也是有好處,印完輕輕ㄧ拉就拿起來了

Bato Wang
2015-04-10 13:44:30

長到10的brim很難剪....尤其有的在內圈很難處理啊.... :'(

戴士偉
2015-04-10 14:11:39

10mm brim +1

可以拿美工小刀割掉阿~~~ XD

Clarence Lee
2015-04-10 14:17:42

不過好像不好修的美...要出動溫控烙鐵了嗎?

Bato Wang
2015-04-10 14:31:37

所以我不愛開Brim....我喜歡老鼠耳朵....然後連接處給他畫的很薄, 印好以後用手折就折的下來了

Clarence Lee
2015-04-10 14:42:37

我有時後會連底都跟著耳朵折下一小角..XD

Bato Wang
2015-04-10 14:45:27

所以耳朵不要畫太厚啊, 而且耳朵太厚的也容易翹.....

廖晉緯
2015-04-10 15:23:41

新手追問一下 老鼠耳朵大概是怎樣弄阿? 我也正在研究怎樣讓大面積的物品邊腳不要翹起

Clarence Lee
2015-04-10 15:33:33

我耳朵+牆角... XD

Bato Wang
2015-04-10 15:36:58

耳朵要夠大才有效.....XD

Clarence Lee
2015-04-10 16:18:45

果然..難怪當時我預到一些狀況還是會翹...
就跟Brim開10mm一樣的道理...
Bato Wang 你耳朵通常厚度抓多薄?

Bato Wang
2015-04-10 16:21:19

最常用的厚度是0.6~1.2mm看東西...重點不是厚度而是面積

Bato Wang
2015-04-10 16:22:13

btw: 我的耳朵經常是半徑20mm的....

Clarence Lee
2015-04-10 16:23:29

根本就是Brim開到20mm等效了.... 難怪都不翹...
/me 已經滾去玩60度熱床了

Bato Wang
2015-04-10 16:25:29

自己的Brim自己畫....哈....

戴士偉
2015-04-10 16:29:46

太薄會被翹起來的角給拉破耳朵 XDDD

重點要自己畫耳朵, 用 slicer 生成的 brim, 擠出時都是跟角一樣形狀, 強度不夠

自己畫的, slicer 會用 45 度去填滿, 強度會高很多.

Clarence Lee
2015-04-10 16:38:46

看來要來弄plugin不過kisslicer比較沒plugin架構
http://www.makerbot.com/....../keep-corners-flat-with....../

戴士偉
2015-04-10 16:46:20

這一招... 聰明耶 XD

陳智遠
2015-04-10 17:29:35

趕快出ATOM熱床套件比較讚..^^

Harry Liu
2015-04-10 19:47:48

也可以用 Kapton, 高溫雙面膠帶

陳世榮
2015-04-11 15:32:29

關側吹風扇,降速度,還有手動熱床-吹風機,可以事先預防,邊吹邊打,或是當做事後藥,當發現開始翹的時候,可以用吹風機熱風吹一下,然後壓回去。

戴士偉
2015-04-11 15:38:24

軟了才能壓, 不然會整片翹起來就GG了 XD


原文網址 劉宏威
2015-04-10 11:40:43

透明料超好玩
用不同列印速度做出的效果


原文網址 陳茂爖
2015-04-10 11:39:27

請問馬達的排線出口要朝上還是下

陳亮宇
2015-04-10 11:46:58

朝左

Stanley Chen
2015-04-10 12:47:55

或朝右...

陳茂爖
2015-04-10 13:03:36

謝謝 也就是說兩邊都可以

葉世瑋
2015-04-10 15:41:09

朝側邊。說明書沒有明講,害我最後得把馬達全部拆下重裝,不然玻璃上不了…


原文網址 吳沂霆
2015-04-10 11:17:27

一大早收成,結果看到印成這樣,噴頭一根拉桿還掉下來,而且底部是翹起來的,囧...有人知道這是什麼原因嗎??

Nobu Hou
2015-04-10 11:18:11

失步之後造成噴頭座跟物件相撞,降速&調整一下皮帶鬆緊,太緊太鬆都會失步

高北熊
2015-04-10 11:19:22

馬達失步,請降低列印速度

吳沂霆
2015-04-10 11:21:38

OKOK~我調整看看~@@...要不然這樣越印越歪~有點冏

Mark Chen
2015-04-10 11:51:29

往哪個方向偏就是那個方向的那一軸有問題 檢查一下事不是同步輪沒鎖緊

吳沂霆
2015-04-10 12:10:43

剛剛看了皮帶~有一條特別鬆~重新調整後~在出發~


原文網址 Winston Shieh
2015-04-10 10:40:53

Auto Home OK, Auto Level OK, start print from SD, the printer stop working. Can anyone help me?

Clarence Lee
2015-04-10 10:46:54

The gcode not correct? looks like moving out of the printable area.
Did you tried the test files ?
https://www.facebook.com/groups/atom3dp/1586312731607016/


原文網址 雷益昇
2015-04-10 09:39:19

感謝這幾天各位大大的回覆,小弟目前還有這個問題,就是在每一層列印的起點都會有個小頓點,這在KISSlicer要調整什麼地方?

Nobu Hou
2015-04-10 11:16:16

降速,降溫,應該就可以解決

Nobu Hou
2015-04-10 11:17:04

如果是用360度起點跟終點,這現象是正常的,你如果單一起點還有這個現象才有問題!

雷益昇
2015-04-10 11:20:05

對。是用360度

Peter Wu
2015-04-10 16:39:28

360度 那欄會隨易散佈每層列印的起始點跟終點,所以會造成這種情況喔,可以調0試試看

廖新弘
2015-04-11 16:50:46

不建議調成0度,之前1.0版時發生過熱堆積


原文網址 Birk Binnard
2015-04-10 08:59:50

My Atom2 is brand new and it fails the AutoHome function. When I try that all three carriers move to the top of their columns and then the whole machine start vibrating pretty badly. So I just switched it off. The LCD says "endstops hit: Y" so I know at least my Y end-stop is working OK.

But how can I find out what the real problem is? I tried using the LCD Move Axis commands and they do work OK - the machine moves the extrude OK i n X, Y, and Z directions.

After this I tried Auto Level and the machine started moving the extruder around to different points in the middle of the build area. I shut it off when the extruder crashed into the X column and knocked the 2 X magnetic rods off their sockets.

I guess the Move Axis commands messed up where the printer thinks it's home position is.

Is there a way to safely test movement commands and the functionality of the 4 limit switches?

Bato Wang
2015-04-10 10:00:57

Hi Birk, please do a factory reset after you upgrade your firmware. prepare->restore failsafe->store memory. And if you want to check endstop value, you can use "M119", it will return the endstop value.

Peter Wu
2015-04-10 10:07:35

Hi Birk. It seems that your microswitches didnt work well, First you have to do what Bato said, prepare ->restore failsafe -> store memory.
Shawn just sent you an attachment named "Mastering Atom 2", you can check how to use pronterface to check your machine's state, Its on page 10 and page11. (y)

Birk Binnard
2015-04-10 10:21:31

Thanks but - my Prepare menu options do not have a Restore Failsafe option. The last one listed is Move Axis.

Birk Binnard
2015-04-10 10:22:24

Perhaps the firmware I loaded was not the correct one. I'm checking on how to do the Pronterface checks now.

Bato Wang
2015-04-10 10:23:40

Hmm...if you don't have it in prepare, check it under "control"....if you want to do it in Pronterface, it is much easier....M502 -> M500 will do the job...

Clarence Lee
2015-04-10 10:25:28

Birk Binnard
2015-04-10 10:32:13

You are correct - I found it there. But pushing the control knob on it does not bring up another set of menus. So I did Restore Failsafe followed by Store Memory, but that didn't seem to have any effect either.

I'll go get Pronterface and see what I can do with that.

Birk Binnard
2015-04-10 10:48:49

Well, Pronterface gets an error trying to connect to the printer. I set Pronterface for COM1 @ 250000 and hit Connect but it gave a bunch of error messages ending with "Cannot configure port, some setting is wrong."

Birk Binnard
2015-04-10 10:50:25

this is not surprising because I do not see the printer in Device Manager. What I do see is UCB Serial Converter listed under Universal Serial Bus, but that's all.

Birk Binnard
2015-04-10 10:58:23

OK - turns out the printer is on COM3. So now I can connect to it.

I think I found the problem (or at least a proble). I clicked the Pronterface Home button and the X slider moved to the top and stopped, but when the Y slicer did that the machine started vibrating. So it's pretty clear there is something wring with the Y limit switch.

Bato Wang
2015-04-10 11:02:27

Try to Move your carriers to the middle, use M119 to print out endstop value, and manually press them one at a time and use M119 to see if they returned ok...you probably will see a axis always return open...and that should be the problem

Birk Binnard
2015-04-10 11:03:38

Well, this is very interesting.

WIth it's power off I manually moved the extruder to the middle of the print space. THen by hand I closed each of the limit switches and ran an m113 from Pronterface. Each time I got the desired response - y_max triggered, z_max triggered, x_max triggered.

So the vertincal limit switches are working OK.

Birk Binnard
2015-04-10 11:18:14

I tried tripping the extruder's limit switch but the m119 command returned with all endstops open. So I may have a problem with the z_min switch in the extruder - but even if I do this should not bother the Home function, should it?

Birk Binnard
2015-04-10 11:28:43

I used Pronterface to set extruder heat = 185C and it reached that temp quite quickly. I checked the temp in the Atom2 LCD and that also said 185C. SO it's good to know that part works OK.

Birk Binnard
2015-04-10 11:36:28

Pronterface moves the extruder as expected by clicking it's X, Y, and Z buttons. So I am still quite confused about what is wrong with the printer.

Peter Wu
2015-04-10 13:00:04

Perhaps you should try re-uploading the firmware to the mainboard
https://www.facebook.com/....../%5BFirmware%5D%20atom2.0.rar

Peter Wu
2015-04-10 14:00:21

or you should recheck the position of limit switch on control board.

Birk Binnard
2015-04-10 15:44:34

Thanks. I will install new (ver. 3) firmware in the morning and check the connections of all 4 limit switches.

Lawrence Lee
2015-04-10 17:12:42

sometimes it could just be the endstop being in the wrong socket, when it homes it always look for X axis endstop first, that can explain one of the carrier hitting top of column violently. Because it's triggering the wrong endstop.

Birk Binnard
2015-04-10 22:40:45

I got the latest firmware uploaded OK. I checked the Extruder head micro-switch and it turns out I had the adjusting screw turned in too much. So I backed it off allowing the limit switch to open. Ialso checked the connections for each of the 4 limit switches - they all look OK.

Now, when I run the m119 command I get x, y, and z max opened and z min triggered. If I manually close the z min limit switch I get z min opened.

Birk Binnard
2015-04-10 22:41:11

This seems backwards - but is it?

Birk Binnard
2015-04-10 22:51:56

I am going to start a new message thread that begins with my current status.

Bato Wang
2015-04-10 23:26:29

Sounds good, Let us focus on your homing issue first.. :)


原文網址 Birk Binnard
2015-04-10 06:20:48

Looks like I wiped out my Atom2's firmware.

Is there a place I can download current Atmo2 firmware and can I use Arduino to install it? Or is there some other way to do that?

Clarence Lee
2015-04-10 07:34:42

Check the files area in this group, find the ATOM2.0.rar

Birk Binnard
2015-04-10 08:11:04

Thanks - I got that and expanded it OK. But what piece of software actually loads the firmware into the Atom2?

Birk Binnard
2015-04-10 08:24:38

Never mind - I figured it out. There is a Marlin.ino file in the Marlin directory that Arduino was able to upload to my Atom2. Now my machine is functional again. Thanks for the pointer to the file.


原文網址 Winston Shieh
2015-04-10 05:05:26

Where should the Heat Shrink Tube apply to?

Birk Binnard
2015-04-10 06:22:21

Good question. I never used either piece.

Lawrence Lee
2015-04-10 18:41:27

on the wires touching the end of extrusion. it act as a protection layer against the sharp edges


原文網址 戴士偉
2015-04-10 02:12:37

自虐的模型
會轉動,但被我轉斷了

戴士偉
2015-04-10 02:20:14

換個角度

李沅融
2015-04-10 03:36:35

厲害@@ 不過我是還在挑戰列印女角裸體 ==+

Lawrence Lee
2015-04-10 17:29:06

試問機器從組裝好到現在有休息過嗎?產出也太驚人了吧

戴士偉
2015-04-10 17:39:50

有阿, 昨天跟今天 XD


 

發文排行榜

回文排行榜

熱門關鍵字